Highlights

  • HWF 10x/22 mm eyepieces
  • Binocular and trinocular models
  • Optional ergonomic tilting head
  • Quintuple revolving nosepiece
  • E-plan, plan and plan Fluarex IOS corrected objectives
  • 187/230 x 140 mm rackless stage with integrated X-Y stage
  • Optional ceramic stage
  • Diascopic intensity adjustable 3 W NeoLED Köhler illumination
  • Epi-fluorescence 100 W HBo mercury vapor
  • Blue and Green LED fluorescence
  • iCare sensor for energy saving
  • State-of-art microscope
  • Excellent optics
  • Suitable for fluorescence applications
  • CSS - Cable Storage System
  • Provided with APL (Antimicrobial Protection Layer)
Models
Specifications
Accessories
Downloads

6-positions rotating attachment

With 100 W mercury vapor light source 
The 6-positions rotating fluorescence attachments are supplied with a standard 100 W HBO mercury vapor light source for broad powerful light spectrum. Supplied with standard fluorescence filters sets for excitation in the blue and green light spectrum and a UV protection shield 

 

MODELS Trinocular WF 10x/22 mm Diopter adjustable on left tube Diopter adjustable on both tubes E-plan EPLi 4x/10x/S40x and S100x objectives Plan PLi 4x/10x/S40x and S100x objectives Plan PLFi 4x/10x/S40 and S100x objectives 100 W HBO light source Filter sets (blue&green) NeoLED illumination  
EIS‑3153‑EPLi‑6
EIS‑3153‑PLi‑6
EIS‑3153‑PLFi‑6

Some models are also available as in vitro diagnostic medical devices class A - (EU) 2017/746
Contact Globe Scientific

3-positions slider attachment

With 100 W mercury vapor light source
The 3-positions slider fluorescence attachments are supplied with standard 100 W HBO mercury vapor light source for broad powerful light spectrum. Supplied with standard fluorescence filters sets for blue and green excitation and a UV protection shield 

 

MODELS Trinocular WF 10x/22 mm Diopter adjustable on both tubes Plan PLi 4x/10x/S40x and S100x objectives Plan PLFi 4x/10x/S40x and S100x objectives 100 W HBO light source Filter sets (blue&green) NeoLED illumination  
EIS‑3153‑PLi‑3
EIS‑3153‑PLFi‑3

Some models are also available as in vitro diagnostic medical devices class A - (EU) 2017/746
Contact Globe Scientific

EYEPIECES
Extended EWF 10x/22 mm eyepieces, Ø 30 mm tubes. Eyepieces can be secured to the tubes. The trinocular head of the Plan infinity corrected models (PLi and PLFi) has a light path selector (100:0 / 50:50) and ± 5 diopter adjustments on both tubes.

The trinocular head of the E-Plan infinity corrected models (EPLi) has a fixed built-in light path beamsplitter (50:50) and ± 5 diopter adjustment on the left tube

HEAD
• Binocular and trinocular Siedentopf type heads with 30° inclined tubes. Interpupillary distance from 48 to 76 mm 
• A unique rotating system allows the ergonomical positioning of both tubes in a high (431 mm) and in a low position (397 mm) 
• The trinocular head has a 23.2 mm photo tube. This fits all C-mount adapters supplied with Euromex cameras 

To order an iScope® with tilting head use reference EIS-3158-xxx (Epli/Pli/PLFi)
To order an iScope® with tilting trino head use reference EIS-3159-xxx (EPLi/Pli/PLFi)

NOSEPIECE
Revolving quintuple reversed nosepiece on ball bearings 

OBJECTIVES
The EPLi and PLi objectives are suitable for Blue and Green standard filter sets and other filter sets in the visible spectrum. 
The plan Fluarex PLFi ™ objectives are suitable for the entire spectrum including Ultra Violet and Violet  

E-Plan EPLi IOS

4x/0.10

10x/0.25

S40x/0.65

S100x/1.25 oil

Plan PLi IOS

4x/0.10

10x/0.25

20x/0.40*

S40x/0.65

S60x/0.85*

S100x/1.25 oil

Plan PLFi IOS

4x/0.13

10x/0.30

20x/0.50*

S40x/0.75

S100x/1.30 oil

* optional 
All optics are anti-fungus treated and anti-reflection coated for maximum light throughput

STAGE
187/230 x 140 mm rackless stage equipped with double slide holder and integrated 79 x 52 mm mechanical stage. The iScope® rackless stage has no protruding parts, enabling more smooth movements and is safer

Optional: 220 x 157 mm ceramic stage with integrated 75 x 50 mm mechanical stage protects with a very tough ceramic surface, against marks and scratches. The surface also ensures stray light not to be reflected from the stage into the objective 

CONDENSER FOR BRIGHTFIELD
The standard height adjustable Abbe N.A. 1.25 condenser for brightfield with magnification indication. 
Also accepts sliders with phase annuli suitable for plan phase 10x/20x or S40x/ S100x oil immersion IOS objectives for economical phase contrast. A slider with a simple dark stop for darkfield up to 400x magnification is also available for this condensor 

CONDENSER FOR ZERNIKE PHASE CONTRAST
An optional height adjustable Zernike NA. 1.25 phase contrast disc condenser with darkfield stop position for darkfield contrast observation up to 400x magnification and plan phase 10/20/S40x and S100x oil immersion PLPHi IOS objectives 

FOCUSING
Coaxial coarse and fine adjustments, 200 graduations, 1 μm per graduation, 200 μm per rotation, total travel range is approximately 24 mm. Supplied with an adjustable rack stop to prevent damage to sample and objectives. The coarse adjustments are equipped with friction control

ILLUMINATION

NeoLED-combined

3 W adjustable Köhler NeoLED diascopic illumination with internal 100-240 V power supply

The innovative NeoLED design offers larger apertures, allowing the optical system of the iScope microscope to produce images at higher resolutions, very close to the theoretical diffraction limit of the optics. Other benefits of the NeoLED is the low energy consumption, no heating and a long operating lifetime

The Köhler illumination on models with IOS plan and plan phase infinity corrected system provides high contrast and a maximum achievable resolving power of the optics. Also available for other models as an option 

ISCOPE_FLUOR_6_blocksILLUMINATION FOR FLUORESCENCE

The 6-position rotating and 3-position slider fluorescence attachments are supplied with:
• a 100 W HBO mercury vapor light source for broad powerful light spectrum. Including an 100-240 V external power supply with indication of the life span of the HBO bulb 

• Standard fluorescence filters sets for 
- blue excitation (EX460- 490 (BP) DM520 EM500 (LP) 
- green excitation (EX510-550 (BP) DM580 EM570 (LP) and a UV protection shield 

The iScope® fluorescence microscopes equipped with a 100 W mercury vapor light source can be supplied with more specific, optimized and application related fluorescence filters sets (see next pages). 

STANDARD GENERAL PURPOSE FLUORESCENCE FILTER SETS

IS.9745

EIS-9745 - Blue excitation filter set
EX: 460-490 nm bandpass DM: 500 nm EM: 520 nm longpass

IS.9746

EIS-9746 - Green excitation filter set
EX: 510-550 nm bandpass DM: 570 nm EM: 580 nm longpass

IS.9747

EIS-9748 - UV excitation filter set
EX: 330-385 nm bandpass DM: 400 nm EM: 420 nm longpass

IS.9748

EIS-9747 - Violet excitation filter set
EX 400-410 nm bandpass DM 455 nm EM 455 nm longpass

ICARE SENSOR
The unique iCare Sensor is developed to avoid unnecessary loss of energy. The illumination of the microscope automatically switches off shortly after microscopists step away from their position

CSS - CABLE STORAGE SYSTEM
iScope allows users to easily insert the power cable into the back of the instrument, which enables easy storage. The integrated carrying grip at the back of the microscope ensures safe transportation of the microscope

CONFIGURATIONS
The iScope microscope is available in many configurations and can be upgraded with a variety of contrast types

PACKAGE CONTENT
Supplied with power cord, dust cover, a spare fuse, user manual and 5 ml immersion oil for models with S100x objective. Models with 100 W mercury vapor light source have a UV protection shield. All packed in polystyrene boxes 

IS.5700 EIS-5700
Ergonomic binocular tilting head 5 to 35°, erect image. Only iScope infinity systems
IS.6210 EIS-6210
EWF 10x/22 mm eyepiece, Ø 30 mm tube
IS.6210-C EIS-6210-C
EWF 10x/22 mm eyepiece with crosshairs, Ø 30mm tube
IS.6210-P EIS-6210-P
EWF 10x/22 mm eyepiece with pointer, Ø 30mm tube
IS.6210-CM EIS-6210-CM
EWF 10x/22 mm eyepiece with 10/100 micrometer and crosshairs, Ø 30mm tube
IS.6212 EIS-6212
WF12.5x/15 mm eyepiece, Ø 30 mm tube
IS.6215 EIS-6215
WF15x/16 mm eyepiece, Ø 30 mm tube
IS.6220 EIS-6220
WF20x/12 mm eyepiece, Ø 30 mm tube
IS.6299 EIS-6299
Pair of eyecups, Ø 30 mm tube
IS.7104 EIS-7104
E-plan EPL 4x/0.10 objective. 0.17 mm cover glass correction. Working distance 15.2 mm
IS.7110 EIS-7110
E-plan EPL 10x/0.25 objective. 0.17 mm cover glass correction. Working distance 5.5 mm
IS.7120 EIS-7120
E-plan EPL 20x/0.40 objective. 0.17 mm cover glass correction. Working distance 3.5 mm
IS.7140 EIS-7140
E-plan EPL S40x/0.65 objective. 0.17 mm cover glass correction. Working distance 0.45 mm
IS.7160 EIS-7160
E-plan EPL S60x/0.85 objective. 0.17 mm cover glass correction. Working distance 0.19 mm
IS.7100 EIS-7100
E-plan EPL S100x/1.25 objective. 0.17 mm cover glass correction. Working distance, 0.13 mm
IS.7710 EIS-7710
Plan PLPH 10x/0.25 phase contrast objective. 0.17 mm cover glass correction. Working distance 12.2 mm
IS.7720 EIS-7720
Plan PLPH 20x/0.40 phase contrast objective. 0.17 mm cover glass correction. Working distance 5 mm
IS.7740 EIS-7740
Plan PLPH S40x/0.65 phase contrast objective. 0.17 mm cover glass correction. Working distance 0.37 mm
IS.7700 EIS-7700
Plan PLPH S100x/1.25 phase contrast objective. 0.17 mm cover glass correction. Working distance 0.13 mm
IS.8804 EIS-8804
E-plan EPLi 4x/0.10 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 15.4 mm
IS.8810 EIS-8810
E-plan EPLi 10x/0.25 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 5.8 mm
IS.8840 EIS-8840
E-plan EPLi S40x/0.65 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 0.43 mm
IS.8800 EIS-8800
E-plan EPLi S100x/1.25 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 0.13 mm
IS.7202 EIS-7202
Plan PLi 2x/0.05 IOS objective for iScope, no cover glass correction. working distance 18.3 mm. Best to be used together with swing-out condenser
IS.7204 EIS-7204
Plan PLi 4x/0.10 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 15.4 mm
IS.7210 EIS-7210
Plan PLi 10x/0.25 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 10 mm
IS.7220 EIS-7220
Plan PLi 20x/0.40 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 5.10 mm
IS.7240 EIS-7240
Plan PLi S40x/0.65 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 0.54 mm
No image EIS-7240
=B580
IS.7260 EIS-7260
Plan PLi S60x/0.85 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 0.14 mm
IS.7200 EIS-7200
Plan PLi S100x/1.25 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 0.13 mm
IS.7200-I EIS-7200-I
Plan PLi S100x/1.25 IOS infinity corrected objective. 0.17 mm cover glass correction and built-in iris diaphragm. Working distance 0.13 mm
IS.7200-W EIS-7200-W
Plan PLi S100x/1.10 IOS water immersion objective. Working distance 0.14 mm. Cover glass 0.17 mm corrected
IS.8910 EIS-8910
Plan PLPHi 10x/0.25 phase contrast IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 10.2 mm
IS.8920 EIS-8920
Plan PLPHi 20x/0.40 phase contrast IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 5.1 mm
IS.8940 EIS-8940
Plan PLPHi S40x/0.65 phase contrast IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 0.5 mm
IS.8900 EIS-8900
Plan PLPHi S100x/1.25 phase contrast IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 0.13 mm
IS.7404 EIS-7404
Plan Fluarex PLFi 4x/0.13 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 16.4 mm
IS.7410 EIS-7410
Plan Fluarex PLFi 10x/0.30 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 12 mm
No image EIS-7420
Plan Fluarex PLFi 20x/0.50 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 1.4 mm
IS.7440 EIS-7440
Plan Fluarex PLFi S40x/0.75 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 0.34 mm
IS.7400 EIS-7400
Plan Fluarex PLFi S100x/1,30 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 0.13 mm
IS.9149 EIS-9149
Telescope for alignment of for phase contrast annuli, Ø 23.2mm tube
IS.9102 EIS-9102
Standard Abbe condenser 1.25 NA with slot for darkfield and phase contrast sliders
IS.9105 EIS-9105
Swing-out 0,9/1,25 condenser
IS.9124 EIS-9124
Zernike phase contrast set PLPH 10/20/40/100 bright fied and dark field position
IS.9127 EIS-9127
Zernike phase contrast set PLPHi 10/20/40/100 IOS bright field and dark field position
IS.9148 EIS-9148
Telescope for phase contrast ø 30 mm tube
IS.9163 EIS-9163
Phase contrast slider set with 20x and S100x oil PLPHi IOS infinity corrected objectives and annuli for 20x/S100x oil
IS.9170 EIS-9170
Slider with dark field stop for iScope
IS.9194 EIS-9194
Slider with phase contrast annuli for S40 phase contast objective for iScope
IS.9600 EIS-9600
Polarization filter 45 mm for lamp house
IS.9601 EIS-9601
Polarization set for iScope: simple rotating polarizer for lamp house and fix polarizer mounted under head
IS.9700 EIS-9700
Blue opaque filter 45 mm for lamp house of iScope
IS.9702 EIS-9702
Green opaque filter 45 mm for lamp house of iScope
IS.9704 EIS-9704
Yellow opaque filter 45 mm for lamp house of iScope
IS.9706 EIS-9706
White opaque filter 45 mm for lamp house of iScope
IS.9749-6 EIS-9749-6
Empty filer block for 6 positions fluorescence attachment of iScope
IS.9749-3 EIS-9749-3
Empty filer block for 3 positions fluorescence attachment of iScope
IS.9749-1 EIS-9749-1
Empty filer block for 1 positions fluorescence attachment of iScope
IS.9753 EIS-9753
Empty rail for 3 positions fluorescence attachment of iScope
IS.9750.39001 EIS-9750-39001
Fluorescence filter set EX435 (BP20) DM455 (LP) EM480 (BP30) optimzed for AmCyan, Atto 425, Cerulean, CFP, ECFP fluorophore. Needs empty filter block (EIS-9749)
IS.9750.39002 EIS-9750-39002
Fluorescence filter set EX480 (BP30) DM505(LP) EM535 (BP40) optimized for Acridine Orange + DNA, Alexa Fluor 488™, Atto 488, Azami Green, BODIPY FL/pH7.2, Calcein, Calcium, Green™-1, Cy2™, DiO, DyLight 488, EGFP, Emerald, GFP, FAM, FITC, Fluo-4, GFP, LysoTracker Green/pH 5.2, MitoTracker Green, FM/MeOH, mWasabi, Oregon Green™ 488, SYBR® Green I, SYTO 9/DNA, ZsGreen fluorophore. Needs empty filter block (EIS-9749)
iS.9750.39003 EiS-9750-39003
Fluorescence filter set EX495 (BP20) DM515 (LP) EM540 (BP30) optimized for Alexa Fluor 514™, Citrine, EYFP/pH 7, F/lAsH-CCPFCC, mCitrine, Oregon Green™ 514, Rhodamine 123, Topaz. Needs empty filter block (EIS-9749)
IS.9750.39004 EIS-9750-39004
Fluorescence filter set EX540 (BP25) DM565 (LP) EM605 (BP55) optimized for Alexa Fluor 546™, Alexa Fluor 555™, Atto 550, CAL, Fluor® Red 590, Cy3™, DiI, DsRed, DyLight 549, MitoTracker Orange/MeOH, Resorufin, Rhod-2, TagRFP, TAMRA tdTomato, Tetramethylrhodamine, isothiocyanate, TRITC. Needs empty filter block (EIS-9749)
IS.9750.39005 EIS-9750-39005
Fluorescence filter set EX540 (BP25) DM565 (LP) EM 620 (BP60) optimized for TRITC-red-shifted, Ethidium homidimer-1/DNA, Propidium Iodide. Needs empty filter block (EIS-9749)
IS.9750.39007 EIS-9750-39007
Fluorescence filter EX620 (BP50) DM655 (LP) EM 690 (BP50) optimized for Alexa Fluor 647™, Allophycocyanin (APC), Atto 647N, Cy5™, DiD, Draq5, DyLight 649 MitoTracker Deep Red 633/MeOH, Nile Blue, Quasar® 670, SYTO® 60, TO-PRO™-3. Needs empty filter block (EIS-9749)
IS.9750.39008 EIS-9750-39008
Fluorescence filter set EX420 (BP40) DM455 (LP) EM 535 (BP40) optimized for Lucifer Yellow/Tetracycline/AlexaFluor 430. Needs empty filter block (EIS-9749)
IS.9750.39009 EIS-9750-39009
Fluorescence filter set EX480 (BP30) DM505 (LP) EM 620 (BP60) for Acridine Orange + RNA, Di-8-ANEPPS, non-ratiometric, DiA, Ethidium Bromide, FM™ 1-43, LysoTracker Yellow HCK-123, Pulsar™ 650. Needs empty filter block (EIS-9749)
IS.9800 EIS-9800
Single photo tube attachment with one 23.2 mm tube for EIS-5700 ergonomic tilting head of iScope® infinity systems
IS.9880 EIS-9880
Köhler attachment
AE.5168-I EAE-5168-I
Heating stage with PID controller up to 50°C. Only supplied with a new iScope microscope
AE.5130 EAE-5130
Universal SLR-adapter with built-in 2x lens for standard 23.2 mm tube. Needs T2 adapter
AE.5025 EAE-5025
T2 ring for Nikon D SLR-digital camera
AE.5040 EAE-5040
T2 ring for Canon EOS SLR-digital camera
PB.5155 EPB-5155
Microscope slides 76 x 26 mm, ground edges, 50 pieces per pack
PB.5160 EPB-5160
Microscope slides 76 x 26 mm with cavity depth 0.25 mm, grinded edges. 10 Pieces per pack
PB.5165 EPB-5165
Cover glasses 18 x 18 mm, 0.13-0.17 mm, 100 pieces
PB.5168 EPB-5168
Cover glasses 22 x 22 mm, 0.13-0.17 mm. 100 pieces
PB.5255 EPB-5255
Immersion oil, 25 ml. Refraction index n = 1.515
PB.5274 EPB-5274
Iso propyl alcohol 99%, 200 ml
PB.5245 EPB-5245
Lens cleaning paper, 100 sheets per pack
PB.5275 EPB-5275
Cleaning kit: lens fluid, lint free lens tissue paper, brush, air blower, cotton swabs
IS.9200-6 EIS-9200-6
6-positions fluorescence attachment iScope with Blue and Green filter sets included, without objectives
IS.9200-6NF EIS-9200-6NF
6-positions fluorescence attachment iScope with 2 empty filter blocks without filters and without objectives
IS.9200-3 EIS-9200-3
3-positions fluorescence attachment iScope with Blue and Green filter sets included, without objectives
IS.9200-3NF EIS-9200-3NF
3-positions fluorescence attachment iScope with 2 empty filter blocks without filters and without objectives
IS.9310 EIS-9310
LED fluor attachment iScope with Green filter set and 520-530 nm LED
IS.9312 EIS-9312
LED fluor attachment iScope with Blue filter set and 460-495 nm LED
No image EIS-9745-6
Filter block with filter set for excitation in Blue spectrum EX460-490 DM520LP EM500LP. Suitable for 6-positions fluorescence attachment
IS.9746-6 EIS-9746-6
Filter block with filter set for excitation in Green spectrum EX510-550 DM580 EM570LP. Suitable for 6-positions fluorescence attachment
No image EIS-9747-6
Filter block with filter set for excitation in Violet spectrum EX400-410 DM455 EM455LP. Suitable for 6-positions fluorescence attachment
IS.9748-6 EIS-9748-6
Filter block with filter set for excitation in UV spectrum EX330-385 DM420 EM400LP. Suitable for 6-positions fluorescence attachment
No image EIS-9745-3
Filter block with filter set for excitation in Blue spectrum EX460-490 DM520LP EM500LP. Suitable for 3-positions fluorescence attachment
No image EIS-9746-3
Filter block with filter set for excitation in Green spectrum EX510-550 DM580 EM570LP. Suitable for 3-positions fluorescence attachment
No image EIS-9747-3
Filter block with filter set for excitation in Violet spectrum EX400-410 DM455 EM455LP. Suitable for 3-positions fluorescence attachment
No image EIS-9748-3
Filter block with filter set for excitation in UV spectrum EX330-385 DM420 EM400LP. Suitable for 3-positions fluorescence attachment
No image EIS-9745-1
Filter block with filter set for excitation in Blue spectrum EX460-495 DM505 EM510-560LP. Suitable for 1-positions fluorescence attachment
No image EIS-9746-1
Filter block with filter set for excitation in Green spectrum EX510-550 DM580 EM510LP. Suitable for 1-positions fluorescence attachment
No image EIS-9211
100-240 Vac/7,5Vdc 1A power supply for single filter block fluorescence attachment
AE.3684 EAE-3684
Glass fuses 500 mA 250 V, 10 pieces
IS.9993 EIS-9993
NeoLED replacement unit for iScope