Highlights

  • Binocular and trinocular models
  • HWF 10x/22 mm eyepieces
  • Reversed nosepiece for maximum 5 objectives
  • Plan, plan fluarex and plan semi apochromatic fluarex ioS objectives
  • Integrated mechanical stage
  • Coaxial coarse and fine adjustments
  • Height adjustable abbe n.a. 1.25 condenser with iris diaphragm and filter holder
  • 3 W lED transmitted illumination
  • Fluorescence attachment for maximum 4 filter blocks and with 100 W mercury vapor incident illuminati
  • Fluorescence attachment with single filter block and 455 nm (Blue), 560 nm (Green) or 365 nm (UV) in
  • Ergonomic stand and head
Models
Specifications
Accessories
Downloads

Oxion Fluorescence

MODELS Binocular Trinocular Plan 4x/10x/ S40x/S100x objectives Plan Fluarex 4x/10x/ S40x/S100x objectives Plan semi apo Fluarex 4x/10x/S40x objectives Plan semi apo Fluarex S100x objectives 100 W mercury vapor illumination 455 nm FluoLED illumination  
OX.3067  
OX.3070  
OX.3075  
OX.3080  
OX.3085
OX.3230
OX.3235  
OX.3232  
OX.3237  

EYEPIECES
• HWF 10x/22 mm eyepieces
• All eyepieces can be secured by an Allen screw

HEAD
• Binocular and trinocular Siedentopf type heads are with 30° inclined tubes 
• Interpupillary distance from 50 to 75 mm
• Two ± 5 diopter adjustments
• A unique rotating system allows the ergonomical positioning of both tubes in a high (431 mm) and in a low position (397 mm)

NOSEPIECE
• Revolving and reversed nosepiece for maximum five objectives 
• The fluorescence models with mercury vapor lamp are equipped with an orange UV protection shield 

OBJECTIVES
• Plan 4x/0.10, 10x/0.25, S40x/0.65 and S100x/1.25 oil immersion IOS objectives 
• Plan Fluarex 4x/0.10, 10x/0.25, S40x/0.65 and S100x/1.30 oil immersion IOS objectives
• Plan semi apochromatic Fluarex 4x/0.13, 10x/0.30, S40x/0.75 and S100x/1.28 oil immersion IOS objectives

All S40x, S60x and S100x oil immersion objectives are spring loaded. All optics are anti-fungus treated and anti-reflection coated for maximum light throughput 

FOCUSING
• Coaxial coarse and fine adjustments, 200 graduations,1 μm per graduation, 200 μm per rotation, total travel range is approximately 28 mm
• Supplied with an adjustable rack stop to prevent damage to sample and objectives
• The coarse adjustments are equipped with friction control

STAGE
• 150 x 140 mm stage with integrated X-Y mechanical stage
• A ceramic stage is also available on request

CONDENSER FOR BRIGHTFIELD
• Height adjustable Abbe condenser N.A. 1.25 with iris diaphragm
• Supplied with a white diffusion filter
• Phase contrast rings mounted in slider can be inserted in the condenser for 10x and S40x or 20x and S100x phase contrast objectives
• A darkfield stop in slider for the 10x, 20x and S40x objectives can also be inserted with magnification indication

CONDENSER FOR FLUORESCENCE
The fluorescence attachment is equipped with an integrated condenser with iris diaphragm and with a field diaphragm

ILLUMINATION FOR BRIGHTFIELD AND PHASE CONTRAST
• All models are supplied with a 3 W adjustable NeoLED illumination with built-in 100-240 V power supply
• Köhler illumination with field diaphragm 

ILLUMINATION FOR FLUORESCENCE
• Fluorescence attachment with 100 W (HBO) mercury vapor incident epi-illumination and rail for maximum four filter blocks
• Two general purpose filter sets are standard supplied with the attachment: AE.3245 (Blue excitation) and AE.3246 (Green excitation)
• Two other general purpose filter sets AE.3246 (UV excitation) and AE.3247 (Ultraviolet excitation) are also available (More specific filter sets are available on request)

STANDARD GENERAL PURPOSE FLUORESCENCE FILTER SETS

AE.3245

AE.3245 (Blue EX 465-495 nm DM 505 nm EM 515-555 nm)

AE.3246

AE.3246 (Green EX 540-580 nm DM 600 nm EM 605-665 nm)

AE.3247

AE.3247 (Violet EX 400-440 nm DM 455 nm EM 465 nm LP)

AE.3248

AE.3248 (UV EX 366-389 nm DM 415 nm EM 435-485 nm)


ILLUMINATION FOR FLUOLED ATTACHMENT

• The FluoLED attachment is standard delivered with a 455 nm LED for efficient and fast detection of tuberculosis with Auramine-O fluorochrome
• FluoLED attachments are also available with a 560 nm LED and Green filter set or a 365 nm LED together with an Ultraviolet filter set

CONFIGURATIONS
The Oxion microscope is available in many configurations and can be upgraded with a variety of contrast types.

PACKAGE CONTENT
• Supplied with power cord, dust cover, white filter, user manual and 5 ml immersion oil for models with S100x objective
• All packed in a polystyrene box 

AE.3210 AE.3210
HWF 10x/22 mm eyepiece
No image AE.3215
HWF 15x/16 mm eyepiece
AE.3223 AE.3223
HWF 10w/22mm eyepiece with 10mm/100 micrometer reticule
AE.3225 AE.3225
Pair of eyecups
AE.3160 AE.3160
Infinity semi plan SMP 4x/0.10 IOS objective. Working distance 21 mm
AE.3162 AE.3162
Infinity semi plan SMP 10x/0.25 IOS objective . Working distance 5.95 mm
AE.3166 AE.3166
Infinity semi plan SMP S40x/0.65 IOS objective. Working distance 0.64 mm
No image AE.3270
Infinity semi plan SMP S100x/1.25 oil immersion IOS objective. Working distance 0.36 mm
AE.3102 AE.3102
Infinity plan PL 2x/0.06 IOS objective
AE.3104 AE.3104
Infinity plan PL 4x/0.10 IOS objective. Working distance 11.9 mm
AE.3106 AE.3106
Infinity plan PL 10x/0.25 IOS objective. Working distance 12.1 mm
AE.3108 AE.3108
Infinity plan PL 20x/0.40 IOS objective. Working distance 1.5 mm
AE.3110 AE.3110
Infinity plan PL S40x/0.65 IOS objective. Working distance 0.36 mm
AE.3112 AE.3112
Infinity plan PL S60x/0.85 IOS objective. Working distance 0.3 mm
AE.3114 AE.3114
Infinity plan PL S100x/1.25 oil immersion IOS objective. Working distance 0.18 mm
86.550 86.550
Plan Fluarex PLF 4x /0,15 infinity corrected IOS objective. Working distance 21.6 mm
86.552 86.552
Plan Fluarex PLF 10x/0.35 infinity corrected IOS objective. Working distance 2.9 mm
86.554 86.554
Plan Fluarex PLF 20x/0.60 infinity corrected IOS objective. Working distance 1.5 mm
86.556 86.556
Plan Fluarex PLF S40x/0.70 infinity corrected IOS objective Working distance 0.6 mm
IS.7400 IS.7400
Plan Fluarex PLFi S100x/1,30 IOS infinity corrected objective. 0.17 mm cover glass correction. Working distance 0.13 mm
AE.3144 AE.3144
Plan semi apochromatic Fluarex PLF 4x/0.13 infinity corrected IOS objective
AE.3146 AE.3146
Plan semi apochromatic Fluarex PLF 10x/0.30 infinity corrected IOS objective
AE.3148 AE.3148
Plan semi apochromatic Fluarex PLF 20x/0.50 infinity corrected IOS objective
AE.3152 AE.3152
Plan semi apochromatic Fluarex PLF S40x/0,75 infinity corrected IOS objective
AE.3156 AE.3156
Plan semi apochromatic Fluarex PLF S100x /1.28 oil immersion infinity corrected IOS objective Working distance 0.21 mm
AE.3190 AE.3190
Polarizer/analyzer set for lamp house and nosepiece
AE.3192 AE.3192
Analyzer mounted in slider for nosepiece
AE.3194 AE.3194
Polarizer for lamp house
AE.3196 AE.3196
White opaque filter 45 mm for lamphouse
AE.3198 AE.3198
Blue filter 45 mm for lamphouse
AE.3200 AE.3200
Yellow filter 45 mm for lamphouse
AE.3202 AE.3202
Green filter 45 mm for lamphouse
AE.3240 AE.3240
Fluorescence illuminator with 100 Watt mercury vapor lamp, inclusive power supply unit and UV protection shield
AE.3245 AE.3245
Fluorescence block with general purpose filter set for Blue EX475BP40, DM505LP,EM535BP45. Excellent for FITC, eGFP. Compatible for 5-carboxyfluorescein (5-FAM), Alexa fluor 488, BODIP-FL, Calcein, Cy2, Dio (Dio 18(3)), eGFP, FITC, Fluo-4, Fluor-Jade, FluorX, iLyte Fluor 488, Mito tracker Green, Rhodamine 110, Spectrumgreen 110, SYTO-13, YO-PRO-1, YOYO-1
AE.3246 AE.3246
Fluorescence block with general purpose filter set for Green EM560BP55, DM595LP, EM645BP75. Excellent for Texas Red, Alexa 594, 5-Carboxynaphthofluorescein. Other compatible fluorophores: 5-CNF, 5-ROX (carboxy-X-rhodamine),Alexa Fluor 568, Alexa Fluor 594, BOBO-3, BODIPY-TR-X, BO-PRO-3, Calcium Crimson, Cy3.5, HcRed, HiLyte Fluor 594, Lissamine rhodamine B, Mito Tracker Red, mPlum mRaspberry, resorufin, Rhodamine Red, R-phycocyanin, SpectrumRed, Texas Red, X-Rhodaline (XRITC), YO-PRO-3, YOYO-3
AE.3247 AE.3247
Fluorescence block with general purpose filter set for Violet EX440BP21, DM455LP, EM480BP30. Compatible fluorophores: BOBO-1, BOPRO-1, Cerulean, CFP, POPO-1, PO-PRO-1, SpectrumAqua, SYTO45, SYTOX Blue
AE.3248 AE.3248
Fluorescence block with general purpose filter set for UV EX365BP50, DM400LP, EM450BP40. Compatible fluorophores: 4-Methylumbelliverone, 7-amino-4methylcoumarin, 7-Hydrixy-4-methylcoumarin (pH9), Alexa Fluor 350, AMCA, AMCA-X, Calcein Blue, Calcein White, Cascade Blue, DAPI, Hoechst 33342 & 33258, LysoSensor Blue (pH5), Lyso Tracker Red, marina Blue, Spectrum Blue
AE.3249 AE.3249
Empty filter block for upright Oxion D25 Dichroic 26x36mm
AE.3250.0401 AE.3250.0401
Fluorescence filter set EX440BP21 DM455LP EM480BP30 optimized for CFP. Compatible with eCFP, mCFPm, Cerulean, CyPet adn SpectrumAqua. This filter set is designed for optimal signal capture of CFP and to minimize spectral bleed-through of YFP. Needs empty block AE.3249
AE.3250.0403 AE.3250.0403
Fluorescence filter set EX380BP50 DM410LP EM450BP60 optimized for BFP, BFP2. Compatible with AlexaFluor 350, DAPI; Hoeschst 33342 & 33258. Wide excitation filter bandwidth may cause cellular damage in live cell applications. Needs empty block AE.3249
AE.3250.0404 AE.3250.0404
Fluorescence filter set EX470BP40 DM500LP EM535BP50 optimized for AlexaFluor 488. Compatible with Cy2, eCFP, FITC and GPT (sapphire). Designed for both excellent brightness and contrast with greater than OD 6 at the excitation/emission crossover. Needs empty block AE.3249
AE.3250.0407 AE.3250.0407
Fluorescence filter set EX635BP30 DM660LP EM710BP80 optimized for AlexaFluor 647. Compatible with Cy5, TOTO-1, TOTO-3, Kodak X-Sight 650. A wide emission filter for maximum photon capture. A narrow excitation filter. Needs empty block AE.3249.
AE.3250.0412 AE.3250.0412
Fluorescence filter set EX500BP25 DM525LP EM545BP35 optimized for YFP and for minimizing CFP bleedthrough. Compatible with AlexFluor 532, Acridine Orange (+DNA), Rhodamine Green . Needs empty block AE.3249
AE.3250.0414 AE.3250.0414
Fluorescence filter set EX560BP55 DM595LP EM645BP75 optimized for Texas Red. Compatible with Texas Red-X, Mito Tracker Red, Cy 3,5, HcRed, mRasberry. Wide passbands that give high brightness and contrast to red emitting fluorophores such as Texas Red. Needs empty block AE.3249
AE.3250.39001 AE.3250.39001
Fluorescence filter set EX435 (BP20) DM455 (LP) EM480 (BP30) optimzed for AmCyan, Atto 425, Cerulean, CFP, ECFP fluorophore. Needs empty filter block (AE.3249)
AE.3250.39002 AE.3250.39002
Fluorescence filter set EX480 (BP30) DM505(LP) EM535 (BP40) optimized for Acridine Orange + DNA, Alexa Fluor 488™, Atto 488, Azami Green, BODIPY FL/pH7.2, Calcein, Calcium, Green™-1, Cy2™, DiO, DyLight 488, EGFP, Emerald GFP, FAM, FITC, Fluo-4, GFP, LysoTracker Green/pH 5.2, MitoTracker Green, FM/MeOH, mWasabi, Oregon Green™ 488, SYBR® Green I, SYTO 9/DNA, ZsGreen fluorophore. Needs empty filter block (OX.3249)
AE.3250.39003 AE.3250.39003
Fluorescence filter set EX495 (BP20) DM515 (LP) EM540 (BP30) optimized for Alexa Fluor 514™, Citrine, EYFP/pH 7, F/lAsH-CCPFCC, mCitrine, Oregon Green™ 514, Rhodamine 123, Topaz. Needs empty filter block (OX.3249)
AE.3250.39004 AE.3250.39004
Fluorescence filter set EX540 (BP25) DM565 (LP) EM605 (BP55) optimized for Alexa Fluor 546™, Alexa Fluor 555™, Atto 550, CAL, Fluor® Red 590, Cy3™, DiI, DsRed, DyLight 549, MitoTracker Orange/MeOH, Resorufin, Rhod-2, TagRFP, TAMRA tdTomato, Tetramethylrhodamine, isothiocyanate, TRITC. Needs empty filter block (OX.3249)
AE.3250.39005 AE.3250.39005
Fluorescence filter set EX540 (BP25) DM565 (LP) EM 620 (BP60) optimized TRITC-red-shifted, Ethidium homidimer-1/DNA, Propidium Iodide. Needs empty filter block (OX.3249)
AE.3250.39007 AE.3250.39007
Fluorescence filter set EX620 (BP50) DM655 (LP) EM 690 (BP50) optimized for Alexa Fluor 647™, Allophycocyanin (APC), Atto 647N, Cy5™, DiD, Draq5, DyLight 649 MitoTracker Deep Red 633/MeOH, Nile Blue, Quasar® 670, SYTO® 60, TO-PRO™-3. Needs empty filter block (OX.3249)
AE.3250.39008 AE.3250.39008
Fluorescence filter set EX420 (BP40) DM455 (LP) EM 535 (BP40) optimized for Lucifer Yellow/Tetracycline/AlexaFluor 430. Needs empty filter block (OX.3249)
AE.3250.39009 AE.3250.39009
Fluorescence filter set EX480 (BP30) DM505 (LP) EM 620 (BP60) for Acridine Orange + RNA, Di-8-ANEPPS, non-ratiometric, DiA, Ethidium Bromide, FM™ 1-43, LysoTracker Yellow HCK-123, Pulsar™ 650. Needs empty filter block (OX.3249)
AE.5168-O AE.5168-O
Stage with heating elements for Oxion series with PID controller, only with new microscopes
OX.9148 OX.9148
Telescope for phase contrast fluorescence alignment
No image OX.9745
Filter block with filter set for excitation in Blue spectrum EX465-495 DM505LP EM515-558 for Oxion Inverso inverted microscope
No image OX.9746
Filter block with filter set for excitation in Green spectrum EX520-600 DM600 EM605-665 for Oxion Inverso inverted microscope
No image OX.9747
Filter block with filter set for excitation in UV spectrum EX361-381 DM415 EM435-495 for Oxion Inverso inverted microscope
No image OX.9748
Filter block with filter set for excitation in Violet spectrum EX361-389 DM415 EM435LP for Oxion Inverso inverted microscope
No image OX.9749
Empty filter block for filters and dichroic mirror for Oxion Inverso inverted microscope
No image OX.9753
Filter block rail, three positions for Oxion Inverso inverted microscope for fluorescence with three empty blocks
OX.9754 OX.9754
Filter block rail, four positions for Oxion Inverso inverted microscope for fluorescence
AE.5120 AE.5120
Standard 23.2 mm tube for Oxion upright (revision 1) and Oxion Inverso inverted microscopes
AE.5120-2 AE.5120-2
Standard 23.2 mm tube for Oxion upright (revision 2) and Oxion Inverso inverted microscopes
AE.5130 AE.5130
Universal SLR-adapter with built-in 2x lens for standard 23.2 mm tube. Needs T2 adapter
AE.5025 AE.5025
T2 ring for Nikon D SLR-digital camera
AE.5040 AE.5040
T2 ring for Canon EOS SLR-digital camera
OX.9833 OX.9833
Photo port adapter with 0.33x lens for Oxion (revision 2) and Oxion Inverso microscopes and 1/3 inch camera with C-mount
OX.9850 OX.9850
Photo port adapter with 0.5x lens for Oxion (revision 2) and Oxion Inverso microscopes and 1/2 inch camera with C-mount
AE.1385 AE.1385
100 W HBO mercury lamp for microscopes with fluorescence attachment
AE.3199 AE.3199
Glass fuses 3.15A 250V, 10pcs
SL.5510 SL.5510
3W NeoLED™ replacement unit for Oxion
PB.5155 PB.5155
Microscope slides 76 x 26 mm, ground edges, 50 pieces per pack
PB.5165 PB.5165
Cover glasses 18 x 18 mm, 0.13-0.17 mm, 100 pieces
PB.5168 PB.5168
Cover glasses 22 x 22 mm, 0.13-0.17 mm, 100 pieces
PB.5245 PB.5245
Lens cleaning paper, 100 sheets per pack
PB.5255 PB.5255
Immersion oil, 25 ml. Refraction index n = 1.482
PB.5274 PB.5274
Iso propyl alcohol 99%, 200 ml
PB.5275 PB.5275
Cleaning kit: lens fluid, lint free lens tissue paper, brush, air blower, cotton swabs
No image AE.3195
Polarizer 360° rotatable for reflected illmination unit
No image AE.3250.0402
Premium fluorescence filter set EX525BP45 DM560LP EM595BP60 optimized High brightness and contrast set for TRITC and other similar fluorophores. Compatible with Alexa Fluor® 555, CoralHue Kusabira Orange, Cy3®, DsRed-Express, DsRed2, MitoTracker® Orange, mOrange, mTangerine, TRITC. Exhibits greater than OD6 attenuation at the excitation/emission crossover. Needs empty block AE.3249
No image AE.3250.0406
Premium fluorescence filter set EX555BP50 DM580LP EM625BP50 optimized for Alexa Fluor 568. Compatible with Alexa Fluor® 568, Alexa Fluor® 594, HcRed, JRed, mCherry, MitoTracker® Red . Exhibits greater than OD6 attenuation at the excitation/emission crossover. Needs empty block AE.3249
No image AE.3250.ND6
Set of 6 pcs neutral density filters, diameter 25 mm consisting of the following: ND 0.10 @ 80% transmittance, ND 0.30 @ 50% transmittance, ND 0.50 @ 32% transmittance, ND 1.0 @ 10% transmittance, ND 2.0 @ 1% transmittance, ND 3.0 @ 0.1% transmittance
No image AE.3250.ND12
Set of 12 pcs neutral density filters, diameter 25 mm, consisting of 1 each of the following: ND 0.05 @ 90% transmittance, ND 0.10 @ 80% transmittance, ND 0.20 @ 63% transmittance, ND 0.30 @ 50% transmittance, ND 0.40 @ 40% transmittance, ND 0.50 @ 32% transmittance, ND 0.60 @ 25% transmittance, ND 0.70 @ 20% transmittance, ND 0.80 @ 16% transmittance, ND 1.0 @ 10% transmittance, ND 2.0 @ 1% transmittance, ND 3.0 @ 0.1% transmittance
No image AE.5127
Standard 23.2 mm tube for Oxion (revision 1)
No image OX.9810
C-mount 1x photo adapter for Oxion (revision 2)
No image OX.5700-ADD
Oxion Ergo Head Add-on price
No image AE.3197-ADD
Oxion ceramic stage Add-on price
No image OX.9750.0402
Premium fluorescence filter set EX525BP45 DM560LP EM595BP60 optimized High brightness and contrast set for TRITC and other similar fluorophores. Compatible with Alexa Fluor® 555, CoralHue Kusabira Orange, Cy3®, DsRed-Express, DsRed2, MitoTracker® Orange, mOrange, mTangerine, TRITC. Exhibits greater than OD6 attenuation at the excitation/emission crossover. Needs empty block OX.9749
No image OX.9750.0406
Premium fluorescence filter set EX555BP50 DM580LP EM625BP50 optimized for Alexa Fluor 568. Compatible with Alexa Fluor® 568, Alexa Fluor® 594, HcRed, JRed, mCherry, MitoTracker® Red . Exhibits greater than OD6 attenuation at the excitation/emission crossover. Needs empty block OX.9749
No image OX.9750.0408
Premium fluorescence filter set EX365 (BP35) DM400LP EM450 (BP60) optimized for DAPI, Alexa Fluor 350. Compatible with AMCA , AMCA-X, DAPI, Hoechst 33258 , Hoechst 33342. Narrow excitation bandwidth. Can decrease phototoxicity of UV light exposure. Needs empty block OX.9749
No image OX.9750.ND6
Set of 6 pcs neutral density filters, diameter 32 mm consisting of the following: ND 0.10 @ 80% transmittance, ND 0.30 @ 50% transmittance, ND 0.50 @ 32% transmittance, ND 1.0 @ 10% transmittance, ND 2.0 @ 1% transmittance, ND 3.0 @ 0.1% transmittance
No image OX.9750.ND12
Set of 12 pcs neutral density filters, diameter 32 mm, consisting of 1 each of the following: ND 0.05 @ 90% transmittance, ND 0.10 @ 80% transmittance, ND 0.20 @ 63% transmittance, ND 0.30 @ 50% transmittance, ND 0.40 @ 40% transmittance, ND 0.50 @ 32% transmittance, ND 0.60 @ 25% transmittance, ND 0.70 @ 20% transmittance, ND 0.80 @ 16% transmittance, ND 1.0 @ 10% transmittance, ND 2.0 @ 1% transmittance, ND 3.0 @ 0.1% transmittance
No image AE.8000
Micromanipulator for intracytoplasmic sperm injection (ICSI) suitable with the Oxion Inverso inverted microscope
SL.1385 SL.1385
100 W Mercury lamp