Highlights

  • Binocular and trinocular models
  • HWF 10x/22 mm eyepieces
  • Reversed nosepiece for maximum 5 objectives
  • Plan, plan fluarex and plan semi apochromatic fluarex ioS objectives
  • Integrated mechanical stage
  • Coaxial coarse and fine adjustments
  • Height adjustable abbe n.a. 1.25 condenser with iris diaphragm and filter holder
  • 3 W lED transmitted illumination
  • Fluorescence attachment for maximum 4 filter blocks and with 100 W mercury vapor incident illuminati
  • Fluorescence attachment with single filter block and 455 nm (Blue), 560 nm (Green) or 365 nm (UV) in
  • Ergonomic stand and head
Models
Specifications
Accessories
Downloads

MODELS Binocular Trinocular Plan 4x/10x/ S40x/S100x objectives Plan fluarex 4x/10x/ S40x/S100x objectives Plan semi apo fluarex 4x/10x/S40x objectives Plan semi apo fluarex S100x objectives 100 W mercury vapor illumination 455 nm FluoLED illumination
OX.3067
OX.3070
OX.3075
OX.3080
OX.3085
OX.3230
OX.3235
OX.3232
OX.3237

EYEPIECE(S)
HWF 10x/22 mm eyepieces. All eyepieces can be secured by an Allen screw

HEADS
Binocular and trinocular Siedentopf type heads are with 30° inclined tubes. Interpupillary distance from 50 to 75 mm. Two ± 5 diopter adjustments. A unique rotating system allows the ergonomical positioning of both tubes in a high (431 mm) and in a low position (397 mm)

NOSEPIECE
Revolving and reversed nosepiece for maximum 5 objectives. The fluorescence models with mercury vapor lamp are equipped with an orange UV protection shield 

OBJECTIVES
• Plan 4x/0.10, 10x/0.25, S40x/0.65 and S100x/1.25 oil immersion IOS objectives 
• Plan fluarex 4x/0.10, 10x/0.25, S40x/0.65 and S100x/1.25 oil immersion IOS objectives
• Plan semi apochromatic fluarex 4x/0.10, 10x/0.25, S40x/0.65 and S100x/1.25 oil immersion IOS objectives

All S40x, S60x and S100x oil immersion objectives are spring loaded. All optics are anti-fungus treated and anti-reflection coated for maximum light throughput 

FOCUSING
Coaxial coarse and fine adjustments, 200 graduations,1 μm per graduation, 200 μm per rotation, total travel approximately 28 mm. Supplied with an adjustable rack stop to prevent damage to sample and objectives. The coarse adjustments are equipped with friction control

STAGE
150 x 140 mm stage with integrated X-Y mechanical stage. A ceramic stage is also available on request

CONDENSER FOR BRIGHTFIELD
Height adjustable Abbe condenser N.A. 1.25 with iris diaphragm. Supplied with a white diffusion filter. Phase contrast rings mounted in slider can be inserted in the condenser for 10x and S40x or 20x and S100x phase contrast objectives. A dark field stop in slider for the 10x, 20x and S40x objectives can also be inserted with magnification indication

CONDENSER FOR FLUORESCENCE
The fluorescence attachment is equipped with an integrated condenser with iris diaphragm and with a field diaphragm

ILLUMINATION FOR BRIGHTFIELD AND PHASE CONTRAST
All models are supplied with a 3 W adjustable NeoLED illumination with built-in 100-240 V power supply. Köhler illumination with field diaphragm 

ILLUMINATION FOR FLUORESCENCE
Fluorescence attachment with 100 W (HBO) mercury vapor incident epi-illumination and rail for maximum 4 filter blocks. Two general purpose filter sets are standard supplied with the attachment: AE.3245 (Blue excitation) and AE.3246 (Green excitation). Two other general purpose filter sets AE.3246 (UV excitation) and AE.3247 (Ultraviolet excitation) are also available. More specific filter sets are available on request

STANDARD GENERAL PURPOSE FLUORESCENCE FILTER SETS

OXION_fluor_graphics

ILLUMINATION FOR FLUOLED ATTACHMENT
The FluoLed attachment is standard delivered with a 455 nm LED for efficient and fast detection of tuberculosis with Auramine-O fluorochrome. FluoLED attachments are also available with a 560 nm LED and Green filter set or a 365 nm LED together with an Ultraviolet filter set

CONFIGURATIONS
The Oxion microscope is available in many configurations and can be upgraded with a variety of contrast types.

• Do you want to see the standard models?
• Do you want to see the phase contrast models?

• Do you want to see the dark field models?
• Do you want to see the inverso (life science) models? 
• Do you want to see the material science models? 
• Do you want to see the inverso (material science) models? 
• Do you want to see the fluorescence models? 

PACKAGING
Supplied with power cord, dust cover, white filter, user manual and 5 ml immersion oil for models with S100x objective. All packed in a polystyrene box 

No image AE.3210
HWF 10x/22 mm eyepiece
No image AE.3215
HWF 15x/13 mm eyepiece
No image AE.3223
HWF 10w/22mm eyepiece with 10mm/100 micrometer reticule
No image AE.3225
Pair of eyecups
No image AE.3160
Infinity semi plan SMP 4x/0.10 IOS objective. Working distance 21 mm
No image AE.3162
Infinity semi plan SMP 10x/0.25 IOS objective . Working distance 5,95 mm
No image AE.3166
Infinity semi plan SMP S40x/0.65 IOS objective. Working distance 0,64 mm
No image AE.3270
Infinity semi plan SMP S100x/1.25 oil immersion IOS objective. Working distance 0,36 mm
No image AE.3102
Infinity plan PL 2x/0,06 IOS objective
No image AE.3104
Infinity plan PL 4x/0.10 IOS objective. Working distance 11,9 mm
No image AE.3106
Infinity plan PL 10x/0.25 IOS objective. Working distance 12,1 mm
No image AE.3108
Infinity plan PL 20x/0.40 IOS objective. Working distance 1,5 mm
No image AE.3110
Infinity plan PL S40x/0.65 IOS objective. Working distance 0,36 mm
No image AE.3112
Infinity plan PL S60x/0.85 IOS objective. Working distance 0,3 mm
No image AE.3114
Infinity plan PL S100x/1.25 oil immersion IOS objective. Working distance 0,18 mm
No image 86.550
Plan Fluarex PLF 4x /0,15 infinity corrected IOS objective. Working distance 21,6 mm
No image AE.3144
Plan semi apochromatic Fluarex PLF 4x/0,13 infinity corrected IOS objective
No image AE.3146
Plan semi apochromatic Fluarex PLF 10x/0,30 infinity corrected IOS objective
No image AE.3148
Plan semi apochromatic Fluarex PLF 20x/0,50 infinity corrected IOS objective
No image AE.3152
Plan semi apochromatic Fluarex PLF S40x/0,75 infinity corrected IOS objective
No image AE.3156
Plan semi apochromatic Fluarex PLF S100x /1,28 oil immersion infinity corrected IOS objective Working distance 0,21 mm
No image AE.3240
Fluorescence illuminator with 100 Watt mercury vapor lamp, inclusive power supply unit and UV protection shield
No image AE.3245
Fluorescence block with general purpose filter set for Blue EX475BP40, DM505LP,EM535BP45. Excellent for FITC, eGFP. Compatible for 5-carboxyfluorescein (5-FAM), Alexa fluor 488, BODIP-FL, Calcein, Cy2, Dio (Dio 18(3)), eGFP, FITC, Fluo-4, Fluor-Jade, FluorX, iLyte Fluor 488, Mito tracker Green, Rhodamine 110, Spectrumgreen 110, SYTO-13, YO-PRO-1, YOYO-1
No image AE.3246
Fluorescence block with general purpose filter set for Green EM560BP55, DM595LP, EM645BP75. Excellent for Texas Red, Alexa 594, 5-Carboxynaphthofluorescein. Other compatible fluorophores: 5-CNF, 5-ROX (carboxy-X-rhodamine),Alexa Fluor 568, Alexa Fluor 594, BOBO-3, BODIPY-TR-X, BO-PRO-3, Calcium Crimson, Cy3.5, HcRed, HiLyte Fluor 594, Lissamine rhodamine B, Mito Tracker Red, mPlum mRaspberry, resorufin, Rhodamine Red, R-phycocyanin, SpectrumRed, Texas Red, X-Rhodaline (XRITC), YO-PRO-3, YOYO-3
No image AE.3247
Fluorescence block with general purpose filter set for Violet EX440BP21, DM455LP, EM480BP30. Compatible fluorophores: BOBO-1, BOPRO-1, Cerulean, CFP, POPO-1, PO-PRO-1, SpectrumAqua, SYTO45, SYTOX Blue
No image AE.3248
Fluorescence block with general purpose filter set for UV EX365BP50, DM400LP, EM450BP40. Compatible fluorophores: 4-Methylumbelliverone, 7-amino-4methylcoumarin, 7-Hydrixy-4-methylcoumarin (pH9), Alexa Fluor 350, AMCA, AMCA-X, Calcein Blue, Calcein White, Cascade Blue, DAPI, Hoechst 33342 & 33258, LysoSensor Blue (pH5), Lyso Tracker Red, marina Blue, Spectrum Blue
No image OX.9750.0401
Premium fluorescence filter set EX440BP21 DM455LP EM480BP30 optimized for CFP. Compatible with eCFP, mCFPm, Cerulean, CyPet adn SpectrumAqua. This filter set is designed for optimal signal capture of CFP and to minimize spectral bleed-through of YFP. Needs empty block OX.9749
No image OX.9750.0403
Premium fluorescence filter set EX380BP50 DM410LP EM450BP60 optimized for BFP, BFP2. Compatible with AlexaFluor 350, DAPI; Hoeschst 33342 & 33258. Wide excitation filter bandwidth may cause cellular damage in live cell applications. Needs empty block OX.9749
No image OX.9750.0404
Premium fluorescence filter set EX470BP40 DM500LP EM535BP50 optimized for AlexaFluor 488. Compatible with Cy2, eCFP, FITC and GPT (sapphire). Designed for both excellent brightness and contrast with greater than OD 6 at the excitation/emission crossover. Needs empty block OX.9749
No image OX.9750.0407
Premium fluorescence filter set EX635BP30 DM660LP EM710BP80 optimized for AlexaFluor 647. Compatible with Cy5, TOTO-1, TOTO-3, Kodak X-Sight 650. A wide emission filter for maximum photon capture. A narrow excitation filter. Needs empty block OX.9749
No image OX.9750.0412
Premium fluorescence filter set EX500BP25 DM525LP EM545BP35 optimized for YFP and for minimizing CFP bleedthrough. Compatible with AlexFluor 532, Acridine Orange (+DNA), Rhodamine Green . Needs empty block OX.9749
No image OX.9750.0414
Premium fluorescence filter set EX560BP55 DM595LP EM645BP75 optimized for Texas Red. Compatible with Texas Red-X, Mito Tracker Red, Cy 3,5, HcRed, mRasberry. Wide passbands that give high brightness and contrast to red emitting fluorophores such as Texas Red. Needs empty block OX.9749
No image OX.9750.39001
Fluorescence filter set EX435 (BP20) DM455 (LP) EM480 (BP30) optimzed for AmCyan, Atto 425, Cerulean, CFP, ECFP fluorophore. Needs empty filter block (OX.9749)
No image OX.9750.39002
Fluorescence filter set EX480 (BP30) DM505(LP) EM535 (BP40) optimized for Acridine Orange + DNA, Alexa Fluor 488™, Atto 488, Azami Green, BODIPY FL/pH7.2, Calcein, Calcium, Green™-1, Cy2™, DiO, DyLight 488, EGFP, Emerald GFP, FAM, FITC, Fluo-4, GFP, LysoTracker Green/pH 5.2, MitoTracker Green, FM/MeOH, mWasabi, Oregon Green™ 488, SYBR® Green I, SYTO 9/DNA, ZsGreen fluorophore. Needs empty filter block (OX.9749)
No image OX.9750.39003
Fluorescence filter set EX495 (BP20) DM515 (LP) EM540 (BP30) optimized for Alexa Fluor 514™, Citrine, EYFP/pH 7, F/lAsH-CCPFCC, mCitrine, Oregon Green™ 514, Rhodamine 123, Topaz. Needs empty filter block (OX.9749)
No image OX.9750.39004
Fluorescence filter set EX540 (BP25) DM565 (LP) EM605 (BP55) optimized for Alexa Fluor 546™, Alexa Fluor 555™, Atto 550, CAL, Fluor® Red 590, Cy3™, DiI, DsRed, DyLight 549, MitoTracker Orange/MeOH, Resorufin, Rhod-2, TagRFP, TAMRA tdTomato, Tetramethylrhodamine, isothiocyanate, TRITC. Needs empty filter block (OX.9749)
No image OX.9750.39005
Fluorescence filter set EX540 (BP25) DM565 (LP) EM 620 (BP60) optimized TRITC-red-shifted, Ethidium homidimer-1/DNA, Propidium Iodide. Needs empty filter block (OX.9749)
No image OX.9750.39007
Fluorescence filter set EX620 (BP50) DM655 (LP) EM 690 (BP50) optimized for Alexa Fluor 647™, Allophycocyanin (APC), Atto 647N, Cy5™, DiD, Draq5, DyLight 649 MitoTracker Deep Red 633/MeOH, Nile Blue, Quasar® 670, SYTO® 60, TO-PRO™-3. Needs empty filter block (OX.9749)
No image OX.9750.39008
Fluorescence filter set EX420 (BP40) DM455 (LP) EM 535 (BP40) optimized for Lucifer Yellow/Tetracycline/AlexaFluor 430. Needs empty filter block (OX.9749)
No image OX.9750.39009
Fluorescence filter set EX480 (BP30) DM505 (LP) EM 620 (BP60) for Acridine Orange + RNA, Di-8-ANEPPS, non-ratiometric, DiA, Ethidium Bromide, FM™ 1-43, LysoTracker Yellow HCK-123, Pulsar™ 650. Needs empty filter block (OX.9749)
No image AE.5120
Standard 23,2 mm tube for Oxion upright (revision 2) and Oxion Inverso inverted microscopes
No image AE.5130
Universal Ø 23.2 mm tube adapter with built-in 2x lens for SLR photo camera with APS-C sensor. Needs T2 adapter
No image AE.5025
T2 ring for Nikon D SLR digital camera
No image AE.5040
T2 ring for Canon EOS SLR digital camera
No image AE.5057
C-mount adapter 0,5x for 1/2 inch cameras for Oxion (revision 1)
No image AE.5058
C-mount adapter 0,33x adapter for 1/3 inch camera for Oxion (revision 1)
No image OX.9833
Photo port adapter with 0,33x lens for Oxion (revision 2) and Oxion Inverso microscopes and 1/3 inch camera with C-mount
No image OX.9850
Photo port adapter with 0,5x lens for Oxion (revision 2) and Oxion Inverso microscopes and 1/2 inch camera with C-mount
No image AE.1385
100 W HBO mercury lamp for microscopes with fluorescence attachment
No image AE.3199
Glass fuses 3.15A 250V, 10pcs
No image SL.5511
3W NeoLED™ replacement unit for Oxion
No image PB.5155
Microscope slides 76 x 26 mm, ground edges, 50 pieces
No image PB.5165
Cover glasses 18 x 18 mm, 0,13-0,17 mm, 100 pieces
No image PB.5255
Immersion oil, 25 ml. Refraction index n = 1,482
No image PB.5274
Iso propyl alcohol 99%, 200 ml
No image PB.5275
Cleaning kit: lens fluid, lint free lens tissue/paper, brush, air blower, cotton swabs