Points essentiels

  • Life science applications
  • Observation of tissue cultures, living cells
  • Brightfield, phase contrast
  • DIC (differential interference contrast)
  • Long working distance IOS plan achromatic objectives
  • Revolving sextuple nosepiece
  • 10 W LED or 100 W halogen transmitted illumination
  • Backwards tilting condenser arm
  • Easy placement of large objects
Modèles
Spécifications techniques
Accessoires
Téléchargements

MODELS LWD Plan phase 10x/20x/S40x objectives 100 W Halogen illumination 10 W LED illumination  
DI.1053‑PLPHFi  
DI.2053‑PLPHFi  

EYEPIECES
Pair of DIN HWF plan 10x/25 mm or 10x/22 mm eyepieces with diopter adjustment

HEAD
Trinocular 45° inclined tubes. Interpupillary distance of 47 to 78 mm. Trinocular head with 100-0, 80/20 and 0/100 positions

NOSEPIECE
Revolving sextuple nosepiece on ball-bearings. The nosepiece can be equipped with DIC prisms for the 10x/20x and 40x objectives

OBJECTIVES 
High numerical infinity semi-apochromatic long working distance plan phase Fluarex PLPHFi 10x/0.30, 20x/0.45, S40x/0.60 IOS objectives enable the sub-cellular structures. An optional 4x/0.13 and 60x/0.70 IOS objective is also available. The 20x, 40x and optional 60 objectives are equipped with collar adjustment ring for glass thicknesses from 0 to 1.2 mm

Fluarex™ objectives are made of low-absorption glass 
Fluarex™ is a trademark of Euromex microscopen bv 
All optics are anti-fungus treated and anti-reflection coated for maximum light throughput

STAGE
Stage 340 x 230 mm, equipped with a coaxial mechanical 130 x 85 mm X-Y stage. Supplied with:
•  Metal insert for ø 38 mm cell culture dish
•  Metal insert for ø 54 mm cell culture dish or 76 x 26 mm slides
•  Metal insert for Multiwell plates (127.76  x 85.48 mm) 
•  Metal insert for Teraski plates (83.3 x 58.0 mm)
•  Optional universal cell culture holder

CONDENSER
Rotating N.A. 0.55 condenser with iris diaphragm. Working distance is 26 mm. Supplied with phase contrast annuli for 10x/20x, 40x and 60x objectives and the DIC prisms for the 10x/20x/40x and 60x objectives. Three filter holders allow the insertion of Ø 38 mm filters in the optical path. The arm with condenser can be tilted backwards for convenient access to the stage. This allows easy placement of large objects like flasks and Petri dishes

LENS CHANGER
A lens changer with a 1.5x lens allows intermediary magnifications of 1.5 times the standard objective magnifications. Switching from 20x to 30x or 40 to 60 and from 60x to 90x magnification can be done without the need to re-focus on the sample

FLUORESCENCE FILTER SET WHEEL
The Delphi-X Inverso is supplied with a 6-position fluorescence filter set wheel. See photo below 

Delphi-X_Inverso_Detail-2

FOCUS ADJUSTMENT
Coaxial 10 mm coarse and fine adjustments, 1 μm precision and with friction adjustment

ILLUMINATION
Transmitted 10 W LED or 100 W halogen Intensity adjustable with internal 100-240 V power supply. Fuse holder 5 A / 250 V. Delphi-X Inverso can be extended with fluorescence equipment

PACKAGE CONTENT
Supplied with metal insert for Ø 38 mm cell culture dish and a metal insert for Ø 54 mm cell culture dish with 76 x 26 mm slides, metal insert for Multiwell plates, metal insert  for Teraski plates, blue and green interference Ø 45 mm filters, power cord, dust cover, green filter and alignment telescope and user manual

ICSI SET
(Intracytoplasmic sperm injection)

•  Perfect for inexperienced users in need of training practice as well as for professionals
•  Complete manual system
•  Large movement range
•  Easy micropipette repositioning 
•  Adjustable micropipette holder angle between 20° and 40°
•  Micropipette holder fixing knob reduces vibration and provides easy handling of the sperm
•  Easy installation and service
•  3D Hydraulic manipulation joysticks for smooth movement
•  Pneumatic Air Injector for ICSI and holding
•  No service required for injector
•  Identical sensitive injectors on both sides and interchangeable
•  Top quality for affordable price
•  Medical device CE mark
•  Movement range: X/Y/Z: 20 mm each, 1 mm for one complete turn of the handle
•  Optional heating stage with controller

Set includes two 3D hydraulic joysticks, two pipette setup mechanisms, one connection bar with moving handle, two air injectors with tubing and pen type micromanipulation, pipette holder, two metal plates for injectors, one set of Allen wrenches, one ruler for mechanic home position adjustment. Unit is packed in a solid carry case

HEATING STAGES AE.8010 AND AE.8015
Heating glass stage for Euromex microscope stage with 110 mm circular hole. The glass plate fits the circular opening of the X-Y stage and enables a flat glass object-plate with constant temperature. The stage has an aluminum frame for superior resistance and flatness. Glass thickness 0.5 mm. Plate diameter 110 mm

Controller AE.8010

AE.8010

•  2-Channel Temperature Controller with touchscreen interface
•  One controller can control up to two devices
•  On-board data logging allows for recording temperature as a function of time and logging calibration events and alarms 
•  The password protected controller is equipped with routines to re-calibrate the sensors against certified thermometers 
•  Temperature range: from ambient to 60°C
•  Temperature accuracy on specimen: ± 0.3°C
•  4.3’’ touch screen interface
•  Alarm buzzer and external alarm connector
•  Self calibration routines enable high temperature accuracy

Controller AE.8015 
(photo: AE.8015 with heating stage)

AE.8015_O

This is the economic and compact single-channel Temperature Controller version of the AE.8010. This model combines performance and simplicity at a economic price
•  Single channel Temperature controller with LCD display temperature control push buttons.
•  Small and robust while maintaining reliability
•  Straight forward in usage
•  Temperature range: from ambient to 60°C
•  Set point Resolution: 0.1°C
•  One-Point Temperature Calibration and Adjustment

Delphi-X_Inverso_Detail-2B

Filters in sliders

No image DI.6010
Super wide field SWF 10x/22 mm focusable eyepiece for Delphi-X Inverso, 30 mm diameter tube
No image DI.6210
Super wide field SWF 10x/22 mm focusable eyepiece for Delphi-X Inverso, 30 mm diameter tube
No image DI.6012
Wide field WF 12.5x/17.5 mm eyepiece for Ø 30 mm tube for Delphi-X Inverso
No image DI.6015
Wide field WF 15x/16 mm eyepiece for Ø 30 mm tube for Delphi-X Inverso
No image DI.6020
Wide field WF 20x/12 mm eyepiece for Ø 30 mm tube for Delphi-X Inverso
No image DI.6099-L
Eyeshade for eyepieces
No image DI.8704
Infinity Plan Semi-Apochromatic Phase contrast Fluarex PLPHFi-Apo 4x/0.13 objective, working distance 16,8 mm. Cover glass correction 1.2 mm
No image DI.8710
Infinity Plan Semi-Apochromatic Phase contrast PLPHFi-Apo 10x/0.30 objective. Working distance 10.2 mm. Cover glass correction 1.2 mm
No image DI.8720
Infinity Plan Semi-Apochromatic Phase contrast PLPHFi-Apo 20x/0.45 objective with collar ring for adjustment of working distance between 7.5 to 8.8 mm. Cover glass correction 1.2 mm
No image DI.8740
Infinity Plan Semi-Apochromatic Phase contrast PLPHFi-Apo 40x/0.60 objective with collar ring for adjustment of working distance between 3 to 4.4 mm. Cover glass correction 1.2 mm
No image DI.9690-10
DIC prism for rotating disc condenser for Life Science Delphi Inverso models. To be used with Plan Semi-Apo 10x objective
No image DI.9690-20
DIC prism for rotating disc condenser for Life Science Delphi Inverso models. To be used with Plan Semi-Apo 20x objective
No image DI.9690-40
DIC prism for rotating disc condenser for Life Science Delphi Inverso models. To be used with Plan Semi-Apo 40x objective
No image DI.9695
DIC polarization filter for transmitted light
No image DI.9810
Adaptateur 1x monture C pour port du microscope inversé Delphi-X Inverso
No image DI.9840
Adaptateur 0,4x monture C pour port du microscope inversé Delphi-X Inverso et caméra à monture C avec un capteur de 1/3 de pouces
No image DI.9850
Adaptateur 0,5x monture C pour port du microscope inversé Delphi-X Inverso et caméra à monture C avec un capteur de 1/2 de pouces