The digital microscopes have equal functions compared to stand-alone microscopes. But since these microscopes have an integrated camera, these are offering a compact solution for viewing microscopy images without having to add an external camera to the microscope
The included software allows the user to view live images on the computer screen or beamer. The software also enables the user to capture images, record videos and perform measurements
The EcoBlue digital microscopes equipped with WF10x/18mm eyepieces, quadruple nosepiece, achromatic objectives, 123 x 119 mm stage with two clamps, Abbe condenser and a 1 W LED illumination

* Models with integrated mechanical stage with 70 x 27 mm X-Y travel range
EYEPIECE(S)
Wide field WF 10x/18 mm eyepiece with pointer
HEAD
Monocular heads with 45° inclined tube and binocular head with 30° inclined tubes, with integrated USB-2 5.0 MP camera
NOSEPIECE
Reversed revolving nosepiece for four objectives on ball bearings
OBJECTIVES
Achromatic 4x/0.10, 10x/0.25, S40x/0.65, S60x and S100x oil immersion objectives (depending on model). The S40x, S60x and S100x oil immersion objectives are spring loaded. All optics are anti-fungus treated and anti-reflection coated for maximum light throughput
FOCUSING
Coaxial coarse and fine adjustments, 200 graduations,12.5 μm per graduation, 2.5 mm per rotation, total travel approximately 15 mm. Supplied with an adjustable rack stop to prevent damage to sample and objectives
STAGES
CONDENSER
Height adjustable, color coded Abbe condenser N.A.1.25 with iris diaphragm and filter holder
DUAL ILLUMINATION SYSTEM
All models are supplied with three rechargeable AA batteries for cordless operation. Equipped with a universal USB-C 5 Vdc charging port and
100-240 Vac / 5 Vdc multiplug adapter
ANTI-THEFT SLOT
At the back of the microscope a Kensington Security Slot is placed, which can be used to secure the instrument from theft
APL (Antimicrobial Protection Layer)
Using the same technology already used extensively throughout the healthcare environment in wall coatings, patient lighting, air pressure stabilization and suction liners, APL prevents the growth of unwanted microbes that can cause degradation, discoloration, staining or odors of the Euromex microscopes
CAMERA
* Frame rates were determined at optimal conditions
SOFTWARE
STORAGE AND TRANSPORTATION


from left to right: EAE-9918 - EAE-9912
PACKAGE CONTENT
EAE-5571
EEC-6010
EEC-6010-M
EEC-6010-P
EEC-6015
EEC-6110
EEC-6099
EEC-7004
EEC-7010
EEC-7020
EEC-7040
EEC-7060
EEC-7000
EEC-9710
EEC-9981
EEC-9991
EAE-5130
EAE-5025
EAE-5040
EPB-5155
EPB-5165
EPB-5168
EPB-5245
EPB-5255
EPB-5274
EPB-5275
EAE-9918
EAE-1110
EAE-5227